Metal roofing underlayment in Edmond, OK is the thin, waterproof layer between your roof deck and metal panels, and it does more to stop a leak than the panels sitting on top of it. Most of the leak calls local crews run on metal roofs trace back to the wrong underlayment, not a bad panel or a loose screw. Here's what actually belongs under a metal roof in central Oklahoma, what code requires, and where most quotes get it wrong.
Metal Roofing Underlayment Types Compared
Three underlayment types show up under metal roofs in Edmond: synthetic sheet, asphalt-saturated felt, and self-adhering ice and water shield. Each behaves differently once summer heat starts radiating off a metal panel, which is the detail that separates a roof that lasts from one that leaks in year six.
| Type | Tear Strength | Heat Tolerance | Best Use Under Metal |
|---|---|---|---|
| Synthetic sheet | High | Good, many are heat-rated for metal | Full-deck coverage on most panel types |
| Asphalt felt | Low to moderate | Poor, can soften or wrinkle | Rarely used alone under metal today |
| Ice and water shield | High | Must be "high-heat" rated, not standard | Eaves, valleys, penetrations |
Synthetic underlayment is a woven polymer sheet that resists tearing and sheds water fast. Synthetic underlayments are 10-15% stronger than felt underlayments, which leads to significantly reduced issues with blow-off and tearing. It has become the default for most metal roofs in this climate.
Felt underlayment is the older, cheaper option. Felt underlayment provides little resistance to air and moisture vapor migration and does not serve as an effective air barrier, which is part of why it has fallen out of favor under metal panels specifically.
Ice and water shield is a self-adhering membrane reserved for eaves, valleys, and roof penetrations. The rubber-like qualities of self-adhering synthetic underlayment make them self-healing, sealing extremely well around fasteners and penetrations, which is why it's also referred to as an ice and water shield. Under metal, though, it has to be the right version, which is where most quotes fall short.
Why Standard Ice and Water Shield Fails Under Metal Panels
This is the detail most Edmond estimates skip entirely. A metal panel in direct July sun gets far hotter than an asphalt shingle, and that heat radiates straight down onto whatever underlayment is beneath it.
High-temperature ice and water shield is built to survive the intense heat under metal roofs, usually rated to at least 240 degrees Fahrenheit, while standard membrane made for cooler asphalt shingle roofs can soften, ooze, and fail if used under metal. Once that happens, the self-sealing adhesive loses its grip around every fastener on the roof.
When standard ice and water shield is installed under metal roofing, it should be formulated to withstand high temps, because if not it can melt and drip out from under the panels. This isn't a cosmetic problem. A softened membrane stops sealing around screw shanks, which is exactly where most metal roof leaks start.
Ask any Edmond contractor point blank whether the ice and water shield in your bid is rated for metal. If they hesitate, that's your answer.

Oklahoma Code Requirements for Metal Roof Underlayment
Underlayment isn't optional, and it isn't a contractor's personal preference either. Underlayment shall comply with Section R905.1.1 of the International Residential Code, which sets minimum material standards and lap requirements by roof covering type and slope.
The code has also caught up with how most roofs actually get built today. IBC 2024 and IRC 2024 permit synthetic underlayment sheets that comply with ASTM D8257 to be used on asphalt shingle, clay and concrete tile, metal shingle, and slate roof systems, which is why synthetic has become the code-recognized standard rather than a premium upgrade.
Your contractor should be able to tell you, without checking, which ASTM designation your underlayment meets and why it satisfies your roof's slope. If a bid just says "underlayment included" with no type or standard listed, ask for specifics before you sign.
How Edmond's Hail and Heat Stress Underlayment
Central Oklahoma sits in one of the more hail-active parts of the country, and that frequency is exactly why underlayment choice carries real weight here. The NWS Storm Prediction Center's climate data shows the average number of 1-inch-plus hail days per year across the state, and the Edmond area falls well inside the higher-frequency bands of that map.
Hail can dent or crack a panel, and once a seam or fastener backs out, the underlayment becomes the only thing standing between that opening and your attic. High wind events common during Oklahoma's spring storm season can also lift panel edges, which exposes whatever underlayment is beneath directly to wind-driven rain.
A roof underlayment matched to Oklahoma's heat-and-hail cycle outperforms one chosen on price alone, especially once you're a few summers in and the cheaper membrane has already started to soften.

Underlayment Needs by Metal Panel Profile
Not every metal roof is built the same way, and the underlayment approach shifts with the panel type.
Standing Seam Metal Roofs
Standing seam panels use concealed fasteners and expand and contract more with temperature swings than exposed-fastener panels. That movement is exactly why a high-heat-rated synthetic or ice and water shield matters more here than almost anywhere else on the roof.
R-Panel, AG Panel & Corrugated Metal
R-panels and AG panels are the most common exposed-fastener profiles across Oklahoma, usually running 26- or 29-gauge steel. They pair well with a full-deck synthetic underlayment, with high-heat ice and water shield concentrated at eaves, valleys, and any low-slope sections.
Stone-Coated & Metal Shingle Roofing
Stone-coated panels and metal shingles are heavier than standard panels, so the deck and underlayment need to handle that added load. A quality synthetic underlayment rated for the panel's heat profile is generally the right call under both.
Signs Your Underlayment Has Already Failed
Several warning signs point to underlayment failure rather than panel damage, and catching them early saves money.
- Ceiling stains or musty attic smells after a rain event
- Visible light coming through gaps in the roof deck
- Condensation buildup in the attic during temperature swings
- Rust streaks forming around fastener heads
- Soft or sagging decking felt underfoot during an inspection
If any of these show up, it's worth scheduling a roof inspection before a small underlayment leak turns into deck rot. Our roof repair team can pinpoint whether the issue starts at the underlayment or somewhere else in the system.
Metal Roofing Underlayment Cost in Edmond, OK
Underlayment cost is rarely broken out on a typical estimate, but it's worth understanding on its own since it drives a real share of the total bid.
| Underlayment Type | Relative Cost per Square | Why |
|---|---|---|
| Felt | Lowest | Cheapest material, shortest service life under metal |
| Synthetic | Moderate | Higher upfront cost, longer field life |
| High-heat ice and water shield | Highest |
Budgeted nationally at around $125 per square, used only in targeted areas like eaves and valleys
|
Panel gauge, roof complexity, and how much tear-off is involved all move the total further than underlayment choice alone. Reflective coatings on some metal panels can also factor into energy costs. To get the emissivity benefit, a metal roof needs to be painted a light color rather than finished with a clear coating, which is worth asking about if energy efficiency is part of your decision.
If you need a square count before you call for quotes, our roofing square calculator guide walks through measuring an Edmond roof step by step.

Hiring the Right Contractor for Underlayment Installation
Chris Archer, owner of A&H Roofing & Contracting, has run crews on Edmond roofs for more than 16 years, and the underlayment layer is the first thing his team checks on every tear-off, since it's usually the real story behind a "mystery" leak. That hands-on habit is why we flag the wrong underlayment type before it ever gets covered by a panel.
A solid written estimate should specify the underlayment brand and type, the ASTM standard it meets, panel gauge, fastener type, and warranty terms, not just a lump-sum number. Using an underlayment that doesn't match your panel manufacturer's spec can void that manufacturer's warranty even when the installation itself is flawless.
Confirm any contractor you're considering is licensed and insured, and ask specifically what underlayment is included in the bid before you compare pricing. Our roofing contractor services cover installation, replacement, and repair for homes throughout Edmond, OK, and you can see the full scope of our work on the homepage.
Request a free estimate and ask us to walk through the underlayment spec line by line before you sign anything.
FAQ
Do metal roofs need special underlayment, or will standard felt work?
Standard felt is not the right call under metal. Metal roof underlayment should carry a high-temperature rating of at least 240 degrees Fahrenheit, since metal panels generate intense heat that can degrade standard products. Felt wasn't built for that heat load and tends to wrinkle or break down faster underneath metal panels.
What is the best underlayment for a metal roof?
For full-deck coverage, a heat-rated synthetic sheet is the standard choice. At eaves, valleys, and penetrations, use a high-heat ice and water shield rated to at least 240 degrees Fahrenheit rather than a standard version.
Can you install a metal roof over existing shingles in Edmond?
In some cases, yes, if local code and the roof structure allow it, but a new underlayment layer is still required between the shingles and the metal panels. For a deeper look at the code details and risks involved, see our guide on metal roof over shingles problems.
What is the 25% rule for roofing?
Many local codes require a full code-compliant re-roof, including underlayment, if more than 25% of the roof surface needs repair or replacement at once. Ask your contractor whether your damage falls under that threshold before approving a repair-only quote.
How many layers of underlayment does a metal roof need?
Most metal roofs get one layer of full-deck synthetic plus a second, high-heat ice and water shield layer concentrated at eaves, valleys, and penetrations. The exact layering depends on your roof's slope and local code requirements under IRC Section R905.1.1.
{ "hero": { "prompt": "Photoreal trade photo, no people, close-up of a newly installed standing seam metal roof on a suburban Oklahoma home with visible synthetic underlayment peeking at the eave edge before final trim, bright daylight, clean modern construction detail, high resolution", "alt": "Standing seam metal roof installation showing synthetic underlayment at the eave on an Edmond, OK home" }, "inline": [ { "id": "inline-1", "prompt": "Photoreal trade photo, no people, close-up macro shot of black high-heat ice and water shield membrane being rolled out and adhered at a roof eave before metal panel installation, visible peel-and-stick backing partially removed, roofing granules and tools nearby, natural daylight", "alt": "Close-up of high-heat ice and water shield membrane being applied at a roof eave before metal panel installation" }, { "id": "inline-2", "prompt": "Photoreal trade photo, no people, close-up of a dented and cracked metal roof panel seam after a hailstorm with the synthetic underlayment visible through the gap, realistic weathering and texture, overcast lighting typical of Oklahoma storm aftermath", "alt": "Hail-dented metal roof panel with exposed seam revealing the underlayment layer beneath" }, { "id": "inline-3", "prompt": "Photoreal trade photo, no people, overhead angle of a residential asphalt and metal combination roof in a suburban Oklahoma neighborhood with a tape measure, clipboard with roof diagram, and chalk line laid out on the roof surface, bright clear day, no visible people or faces", "alt": "Roofing estimator measuring a residential roof in Edmond, OK with a tape measure and clipboard" } ] }